Do you have any questions about our products? Our experts will be glad to assist you! Just give us a call +358 20 7789810

Tuotevertailut 2 tuotteille

 Lähetä
Tuote
Tekniset tiedot
Cable length:
Electrical data | Supply
Operating voltage AC max.:
Operating voltage DC max.:
Current operating per contact max.:
Device protection | Electrical
Degree of protection (EN IEC 60529):
Additional condition protection degree:
Rated surge voltage:
Device protection | Media
Flame resistance:
Mechanical data | Material data
Color housing:
Material housing:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Cable data
Cable
wire arrangement:
General data | Cable
Cable identification:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Max. rated voltage (conductor - conductor):
Max. rated voltage (conductor - ground):
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (dynamic):
No. of bending cycles (C-track):
Traversing distance (C-track):
Travel speed (C-track):
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Kaupalliset tiedot
GTIN:
Tullinumero:
Pakkauskoko:
Siirrä tuote
Valve plug MJC 90° with cable Valve plug MJC 90° with cable
PUR 2x0.5 bk drag ch. 3m
Paino: 0.115 kg
Tuotenro.: 7000-70301-7400300

Saatavilla
Siirrä tuote
Valve plug MJC 0° with cable Valve plug MJC 0° with cable
PUR 2x0.5 bk drag ch. 3m
Paino: 0.115 kg
Tuotenro.: 7000-70001-7400300

Kysykää tuotteen saatavuutta asiakaspalvelusta
3 m
3 m
230 V
230 V
230 V
230 V
4 A
4 A
IP65
IP65
inserted, locked
inserted, locked
4 kV
4 kV
flame retardant
flame retardant
black
black
Plastic
Plastic
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
black, white
black, white
740
740
black
black
-
-
1
1
2 wires twisted
2 wires twisted
black, white
black, white
36,3 g/m
36,3 g/m
PUR
PUR
85 Shore A
85 Shore A
lead-free, cadmium-free, CFC-free, halogen-free
lead-free, cadmium-free, CFC-free, halogen-free
5 mm
5 mm
± 5 %
± 5 %
TPE-E
TPE-E
2
2
1,5 mm
1,5 mm
± 5 %
± 5 %
70 Shore A
70 Shore A
lead-free, CFC-free, halogen-free
lead-free, CFC-free, halogen-free
64
64
0,1 mm
0,1 mm
0,5 mm²
0,5 mm²
Stranded copper wire, bare
Stranded copper wire, bare
strand class 6
strand class 6
500 V
500 V
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
9 A
9 A
39 Ω/km @ 20 °C
39 Ω/km @ 20 °C
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
2 kV @ 60 s
-50 °C
-50 °C
90 °C
90 °C
-30 °C
-30 °C
90 °C
90 °C
-
-
-
-
-
-
-
-
DIN EN ISO 4892-2 A
DIN EN ISO 4892-2 A
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
Good, application-related testing | DIN EN 60811-404
10 x Outer diameter
10 x Outer diameter
2 Mio. @ 25 °C
2 Mio. @ 25 °C
5 m @ 25 °C | horizontal
5 m @ 25 °C | horizontal
3,3 m/s @ 25 °C
3,3 m/s @ 25 °C
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27060312
27060312
27060312
27060312
27060312
27060312
27060312
27060312
EC001855
EC001855
4048879285742
4048879135771
85444290
85444290
1
1
* plus alv., plus toimituskulut