Do you have any questions about our products? Our experts will be glad to assist you! Just give us a call +358 20 7789810

Tuotevertailut 2 tuotteille

 Lähetä
Tuote
Tekniset tiedot
Cable length:
Side 1
Tightening torque:
Thread:
Degree of protection (EN IEC 60529):
Side 2
Tightening torque:
Thread:
Degree of protection (EN IEC 60529):
Electrical data
Capacity CX:
Electrical data | Supply
Operating voltage AC:
Operating voltage AC min.:
Operating voltage AC max.:
Operating voltage DC:
Operating voltage DC min.:
Operating voltage DC max.:
Cut-off peak voltage max.:
Current operating per contact max.:
Current consumption max.:
Diagnostics
Status indication LED:
Device protection | Electrical
Additional condition protection degree:
Rated surge voltage:
Mechanical data | Material data
Color housing:
Material housing:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Cable data
General data | Cable
Cable identification:
Cable Type:
Printing color of wire insulation:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
wire arrangement:
Mechanical data | Cable
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Material properties wire insulation:
Ingredient freeness wire insulation:
Printing color of wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Max. rated voltage (conductor - conductor):
Max. rated voltage (conductor - ground):
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Kaupalliset tiedot
Pakkauskoko:
Tullinumero:
GTIN:
Hyväksynnät
Certificates
Certificate
Siirrä tuote
M12 male 90° A-cod. / MSUD valve plug B-10mm M12 male 90° A-cod. / MSUD valve plug B-10mm
PVC 3x0.75 ye 1.5m
Paino: 0.129 kg
Tuotenro.: 7000-41021-0160150

Kysykää tuotteen saatavuutta asiakaspalvelusta
Siirrä tuote
M12 male 90° A-cod. / MSUD valve plug B-10mm M12 male 90° A-cod. / MSUD valve plug B-10mm
PVC 3x0.75 gy 5m
Paino: 0.329 kg
Tuotenro.: 7000-41021-2160500

Kysykää tuotteen saatavuutta asiakaspalvelusta
1,5 m
5 m
0,4 Nm
0,4 Nm
M3
M3
IP66K, IP67
IP66K, IP67
0,6 Nm
0,6 Nm
M12 x 1
M12 x 1
IP66K, IP67
IP66K, IP67
20 ms
20 ms
24 V
24 V
19,2 V
19,2 V
28,8 V
28,8 V
24 V
24 V
18 V
18 V
30 V
30 V
55 V
55 V
4 A
4 A
12 mA
12 mA
yellow
yellow
inserted, screwed
inserted, screwed
0,8 kV
0,8 kV
black
black
Plastic
Plastic
inserted, screwed
inserted, screwed
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
016
216
1
1
white (isolation black)
white (isolation black)
yellow
gray
-
-
1
1
3 wires twisted
3 wires twisted
black 1, black 2, green-yellow
black 1, black 2, green-yellow
63,8 g/m
63,8 g/m
PVC
PVC
80 ± 5 Shore A
80 ± 5 Shore A
lead-free, cadmium-free, CFC-free, silicone-free
lead-free, cadmium-free, CFC-free, silicone-free
5,9 mm
5,9 mm
± 5 %
± 5 %
PVC
PVC
3
3
1,8 mm
1,8 mm
± 5 %
± 5 %
43 ± 5 Shore D
43 ± 5 Shore D
good machinability
good machinability
lead-free, cadmium-free, CFC-free, silicone-free
lead-free, cadmium-free, CFC-free, silicone-free
white (isolation black)
white (isolation black)
24
24
0,2 mm
0,2 mm
0,75 mm²
0,75 mm²
Stranded copper wire, bare
Stranded copper wire, bare
Strand class 5
Strand class 5
500 V
500 V
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
12 A
12 A
26 Ω/km @ 20 °C
26 Ω/km @ 20 °C
3 kV @ 60 s
3 kV @ 60 s
3 kV @ 60 s
3 kV @ 60 s
-30 °C
-30 °C
70 °C
70 °C
-5 °C
-5 °C
70 °C
70 °C
-
-
-
-
-
-
-
-
-
-
IEC 60332-2-2 | UL 1581 § 1100 FT2 | UL 1581 § 1090
UL 1581 § 1090 | IEC 60332-2-2 | UL 1581 § 1100 FT2
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
Good, application-related testing | DIN EN 60811-404
5 x Outer diameter
5 x Outer diameter
10 x Outer diameter
10 x Outer diameter
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27279218
27060312
27060312
27060312
27060312
27060312
27060312
27060312
27060312
EC001855
EC001855
1
1
85444290
85444290
4048879609975
4048879335560
* plus alv., plus toimituskulut