Do you have any questions about our products? Our experts will be glad to assist you! Just give us a call +358 20 7789810

Tuotevertailut 2 tuotteille

 Lähetä
Tuote
Tekniset tiedot
Cable length:
Side 1
Tightening torque:
Mounting method:
Family construction form:
Thread:
suitable for corrugated tube (internal Ø):
Coding:
Material:
Width across flats:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage AC max.:
Operating voltage DC max.:
Current operating per contact max.:
Installation | Connection
Mounting set:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Mechanical data | Material data
Coating locking:
Coating of fitting:
Material gasket:
Locking material:
Material screw connection:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Cable data
General data | Cable
Cable identification:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
wire arrangement:
Mechanical data | Cable
Material jacket:
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Travel speed (C-track):
Classifications
ECLASS-6.0:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Kaupalliset tiedot
GTIN:
Tullinumero:
Pakkauskoko:
Hyväksynnät
Certificates
Certificate
Certificate
Certificate
Siirrä tuote
M8 female 0° with cable M8 female 0° with cable
PUR 8x0.14 1,5m
Paino: 0.052 kg
Tuotenro.: 7000-08961-6960150

Saatavilla
Siirrä tuote
M8 female 0° with cable M8 female 0° with cable
PUR 8x0.14 bk 2m
Paino: 0.067 kg
Tuotenro.: 7000-08961-6960200

Saatavilla
1,5 m
2 m
0,4 Nm
0,4 Nm
inserted, screwed
inserted, screwed
M8
M8
M8 x 1
M8 x 1
8 mm
8 mm
A
A
PUR
PUR
SW9
SW9
IP67
IP67
30 V
30 V
30 V
30 V
1,5 A
1,5 A
M8 x 1
M8 x 1
inserted, screwed
inserted, screwed
3
3
Nickeled
Nickeled
nickel plated
nickel plated
NBR
NBR
Zinc die-casting
Zinc die-casting
Zinc die-casting
Zinc die-casting
inserted, screwed, Shaking protection
inserted, screwed, Shaking protection
-30 °C
-30 °C
80 °C
80 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
696
696
black
black
-
-
1
1
8 wires around Filler twisted
8 wires around Filler twisted
white, brown, green, yellow, gray, pink, blue, red
white, brown, green, yellow, gray, pink, blue, red
PUR
PUR
5,5 mm
5,5 mm
± 5 %
± 5 %
PP
PP
8
8
1,07 mm
1,07 mm
± 5 %
± 5 %
18
18
0,1 mm
0,1 mm
0,14 mm²
0,14 mm²
Stranded copper wire, bare
Stranded copper wire, bare
strand class 6
strand class 6
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
4,8 A
4,8 A
78 Ω/km @ 20 °C
78 Ω/km @ 20 °C
3 kV @ 60 s
3 kV @ 60 s
3 kV @ 60 s
3 kV @ 60 s
-30 °C
-30 °C
80 °C
80 °C
-15 °C
-15 °C
80 °C
80 °C
-
-
-
-
-
-
-
-
-
-
IEC 60332-2-2 | UL 1581 § 1100 FT2 | UL 1581 § 1090
IEC 60332-2-2 | UL 1581 § 1100 FT2 | UL 1581 § 1090
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
Good, application-related testing | DIN EN 60811-404
6 x Outer diameter
6 x Outer diameter
2 Mio. @ 25 °C
2 Mio. @ 25 °C
27279218
27279218
27279218
27279218
27279218
27279218
27060311
27060311
27060311
27060311
27060311
27060311
27060311
27060311
EC001855
EC001855
4048879550147
4048879664882
85444290
85444290
1
1
* plus alv., plus toimituskulut