Do you have any questions about our products? Our experts will be glad to assist you! Just give us a call +358 20 7789810
Zoom
IMPACT67 E DIO16 4P
Tuote voi erota kuvan tuotteesta

IMPACT67 E DIO16 4P

IMPACT67 EthernetIP compact module, plastic housing,
Tuotenro.: 55142
Paino: 0.487 kg
  Tuotantovaiheessa
 Tuotevertailu
Listahinta / kpl:

Voisit olla kiinnostunut myös näistä

Digital inputs/outputs
DIO16
Ethernet 10/100 Mbit/s; M12, D-coded
7/8", 4-pole, 2× max. 9 A
M12, 5-pole, A-coded
DLR (Device Level Ring)
Connection cables are in the online shop under "Connection Technology". Housing fully potted.
Input
Sensor supply US 24 V DC (EN 61131-2), max. 200 mA (M12 female), short-circuit and overload protected
Type for 3-wire sensors or mechanical switches, PNP
Connections
Fieldbus Ethernet 10/100 Mbit/s; M12, D-coded
Sensor-system/actuator supply 7/8", 4-pole, 2× max. 9 A
I/O ports M12, 5-pole, A-coded
General data
Protection IP67
Mounting method 2-hole screw mounting, compatible with I/O modules of MVK model range
Dimensions H×W×D 39×63×225 mm
Temperature range -25...+55 °C (storage temperature -40...+85 °C)
EtherNet/IP
Addressing DHCP, BOOTP or IP address by DIP switch
QC (Quick Connect) max. 360 ms
Multiple connections yes
CIP Sync yes
Composite Test Revision CT14
DLR (Device Level Ring) yes
Output
Actuator supply UA 24 V DC (EN 61131-2), max. 9 A
Switching current per output max. 1.6 A (short-circuit and overload protected)
Lamp load 10 W
Parameterization
PIN 4 Input/Output (port X0...X7)
PIN 2 Input/Output (port X0...X7)
Diagnostic
Communication status via LED
Diagnostic via LED per module and channel
Diagnostic via BUS per module and channel
Monitoring - under voltage yes
Monitoring - no voltage yes
Short-circuit and overload yes
Actuator warning per channel via LED and BUS
Kaupalliset tiedot
Alkuperämää DE
EAN 4048879699723
eClass 27242604
Pakkauskoko 1
Tullinumero 85389099
 
Tuotetietoja:
  • Lataus Datalehti
  • Lataus Approvals and certificates 55142_E201820-NRAQ_ul_z_a.pdf
  • Lataus Approvals and certificates 55142_E201820-NRAQ7_ulc_z_a.pdf
  • Lataus Approvals and certificates 55142_17-05.18_ce_z_a.pdf
  • Lataus China RoHS information EPUP-25_CHR_x_1.pdf
  • Lataus Configuration Files 55142_IMPACT67_Kfg_x_14.zip
  • Lataus Drawing Files 55142_stp_x_a.zip
  • Lataus Drawing Files 55142_dxf_x_a.zip
  • Lataus Drawing Files 55142_p8_2_30.zip
  • Lataus Installation Instructions 55142_ina_x_10.zip
  • Lataus Manuals 55142_hdb_x_12.zip
cULus
cCSAus
* plus alv., plus toimituskulut